EXAMPLES OF PROGRAMMATION
MANUAL 100 pulse/min
Press the F button and select the F1 function. Press Enter and while the display is blinking select 100 by
pressing Up e Down, press Enter to confirm, the green Led will light up and the pump will work.
PROPORTIONAL to the Rx measure with a set-point of 350mV, maximum flow of 80 injections
per minute for an Rx value of 500mV.
After having calibrated the probe, choose the Rx set-point, the extreme value (L1) of the proportional
interval and the maximum number of injections per minute as follows:
Press the F button until the function Set – set-point function.
Press the Enter button to confirm the choice. Modify the reading pressing the UP and DOWN buttons
until the value of 350mV and then press Enter to confirm.
Press the F button until the function L1 – proportional function- will appear.
Press Enter to confirm the choice. Set the value 500mV by pressing the UP and DOWN buttons and
confirm by Enter.
Press the F button until the function F2 – maximum proportional flow function- will appear.
Press Enter to confirm the choice. Set the value 80 by pressing the UP and DOWN buttons and
confirm by Enter.
The green Led will light up and the pump will work.
13/11/13
ADSP7000181A Rev.2.2
9