DESCRIPTION OF FUNCTIONS

F1 Manual Mode:
The pump runs at a constant rate just like a manual pump. The display shows the number of injections per
minute which can be set by programming any number from 0-105 pulses/min. This function is useful when
priming the pump from new at the time of the installation.
F2 Maximum number of injection per minute in proportional mode:
The pump runs in proportional mode. The display shows the maximum number of injections per minute in
proportional mode. This frequency can be set by programming from 000 to 105 pulses/min.
L1 Proportional Mode:
The pump runs proportionally according the difference between the measured reading and the Rx setpoint
set in L1.
CAL Probe Calibration:
The pump is ready for probe Calibration
SET Set-point Adjustment:
The pump is ready for setpoint to be adjusted.
LOW LEVEL ALARM (with ADSLG probe)
When stopped the pump will display the words Lo. A small time delay of a 5 seconds is present to eliminate
nuisance switching caused by ripples on the surface of chemical. The pump restarts automatically when the
chemical level is restored.