Advanced Programming Options
Features Table
FEATURE
PARAMETER
MODE
1
HOME ANTIFREEZE
2
HOME ANTIFREEZE
3
T°
ADJUST T° Z1
4
FREQ REDUCT
5
MODE
FREQ REDUCT
6
ROOM MODE
7
CTRL ROOM SP Z1
8
ROOM AIR T° W1
9
RH SENSOR VALUE
10
OUTDOOR T°O
11
GMC OAT
12
TROOM SENSOR
13
ADJ Z1
DAY PERIOD
14
HOME HEAT T°
15
HOME COOL T°
16
SLEEP HEAT T°
17
SLEEP COOL T°
18
AWAY HEAT T°
19
AWAY COOL T°
20
USER ROOM SP Z1
21
FAULT CODE
22
FAULT HISTORY
23
The parameters which are Read-Only and are not editable, Key pad lock (
Only parameter numbers are given below.
Parameter Number: 7, 8, 9, 10, 11, 12, 21, 22 and 23
DESCRIPTION
This is the selectable Mode:
0. Off
2. Cooling
3. Heating
This parameter enables the Home Antifreeze
option when the system is Off:
1. NO. Disable
2. YES. Enable
Home Antifreeze threshold Temperature value
Water set point adjustment for
room temperature at
zone
This code gives information whether Silence
mode / Frequency Reduction/ Night mode is
active
1. Not Active
2. Active
Value of the frequency reduction in % of CDU
will display this parameter
1. Home
2. Sleep
3. Away
This code is the control Room Set-point
determined by pressing the Home, Sleep, Away
buttons
This is the room air Temperature read by
the internal
Thermistor
This is the relative Humidity value from the
sensor
Outdoor Temperature measured by the TO
sensor (reading value).
OAT from
board
Temperature sensor adjustment to recover bad
user interface positioning error
This Parameter says about the periods per day
will be available for the scheduling:
1. 2
2. 4
3. 6
HOME Temperature set-point in Heating mode
HOME Temperature set-point in Cooling Mode
SLEEP Temperature set-point in Heating Mode
SLEEP Temperature set-point in Cooling Mode
AWAY Temperature set-point in Heating mode
AWAY Temperature set-point in Cooling Mode
Room set point
Fault codes will be scrolled @ 1 second
Stores the recent 4 fault codes
ICON
Current Mode (and
new when changed)
Antifreeze
°C
°C
Arrow depending by
Room mode
°C
°C
%
°C
°C
°C
°C and the arrow for
Home
°C and the arrow for
Home
°C and the arrow for
Sleep
°C and the arrow for
Sleep
°C and the arrow for
Away
°C and the arrow for
Away
°C
) icon will be displayed on the screen for those parameters. The list of Read-
VALUE RANGE
DEFAULT
Min
Max
VALUE
-
-
0
1
2
1
6°C
12°C
6°C
-5°C
+5°C
0°C
1
2
1
50%
100%
75%
1
3
1
12°C
38°C
20°C
-20°C
50°C
0
100
-30°C
90°C
-20°C
65°C
-5°C
5°C
0°C
2
6
4
12°C
38°C
20°C
12°C
38°C
24°C
12°C
38°C
18°C
12°C
38°C
26°C
12°C
38°C
15°C
12°C
38°C
28°C
12°C
38°C
20°C
3
31
3
31
13