Troubleshooting; Technical Data - Oase CrystalSkim 350 Instrucciones De Uso

Ocultar thumbs Ver también para CrystalSkim 350:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Troubleshooting

Malfunction
Pump does not start
Water flow insufficient
Insufficient filtering per-
formance

Technical data

CrystalSkim (USA version)
Rated pump voltage
Pump supply frequency
Pump power consumption
Pump conveying performance
Max. aquarium size
Dimensions
(excluding holding fix-
ture)
Length of the connection cable
Weight
12
Possible cause
No power supply
Impeller unit blocked
Water inlet clogged
Impeller unit worn
Foam filter clogged
Foam filter clogged or worn
Water inlet blocked
AC V
Hz
W
gph
l/h
gal
l
Diameter
in
Height
in
Diameter
mm
Height
mm
ft
m
oz
g
Remedy
Check power supply
Clean
Clean the housing and
impeller unit
Replace impeller unit
Clean the foam filter
Clean or, if necessary,
replace foam filter
Clean
350
600
120
120
60
60
4
4
60 ... 80
120 ... 180
220 ... 320
450 ... 680
92.5
158.5
350
600
1,4
1,9
4,6
6,7
36
49
116
170
6.6
6.6
2
2
7.4
8.8
210
250
Tabla de contenido
loading

Este manual también es adecuado para:

Crystalskim 600

Tabla de contenido