2
INSTALLATION
Installation.is.permanent.and.must.exclusi-
vely.be.performed.by.specialised.and.quali-
fied.personnel,.following.all.the.instructions.
and. provisions. included. in. this. manual..
Current.regulations.must.also.be.met.
2.1
SUPPLY (fig. 4)
MURELLE EQUIPE 100-150 BOX ErP heat.
modules,. inter-connectible. by. flange,. are.
supplied.with.an.external.pre-painted.zinc-
coated.laminate.case..
They.are.complete.with.supply/return.water.
manifold. fastening. screws. and. manifold.
gas,.external.temperature.probe.kit,.casca-
de.supply.and.RS-485.code.8092250.board.
connection.cable.
Available.separately:
–. Tubes. connecting. the. hydraulic. separa-
tor. kit. code. 8101534. for. left-hand. fixtu-
res.for."100-150 BOX ErP".
–. Single. box. (size:. 630. x. 640. x. 1600). for.
hydraulic.separator,.code.8101517.(figu-
re.4).
–. Hydraulic.separator.kit.code.8101550.for.
"100-150 BOX ErP".
SINGLE BOX FOR
BOX CONTENITORE SINGOLO PER
HYDRAULIC SEPARATOR AND TUBES CONNECTING
SEPARATORE IDRAULICO E KIT SICUREZZE INAIL
code 8101517
cod. 8101517
NOTICE: The supply and return of the hydraulic compensator can be positio-
ned on the right or left-hand side of the box by moving the connection flange
secured with six screws.
–. Polypropylene. exhaust. manifold. kit. for.
indoor. installation. (purposely. treated. to.
resist. weathering. when. installed. outdo-
ors):
. code.8102511.for."100 BOX ErP" module
. code.8102512.for."150 BOX ErP" module
–. Exhaust. terminal. code. 8089530. for.
outdoor.installations.
To.electrically.connect.the.modules.and.to.
assemble.the.exhaust.for.indoor.or.outdoor.
installations,.see.points.2.6,.2.7.and.2.10.in.
1100 (Murelle Equipe
this.manual.
100-140 BOX ErP)
415
260
675
2.2
INSTALLATION
2.2.1
Indoors
MURELLE EQUIPE 100-150 BOX ErP heat.
modules. can. be. installed. in. boiler. rooms.
whose.size.and.requirements.meet.current.
regulations..
Furthermore,. vents,. with. surface. areas. at.
least..3.000.sq..cm..or..5.000.sq..cm.for.gas.
with. density. over. 0.8,. must. be. installed. in.
45
630
the.outer.walls.for.room.ventilation..
2.2.2
MURELLE EQUIPE 100-150 BOX ErP heat.
modules. can. also. be. installed. outdoors.
with.the.specific.exhaust.for.single.module.
code.8089530.
2.3
630
To.protect.the.heat.system.from.damaging.
1730
corrosion,. incrustation. or. deposits,. after.
installation. it. is. extremely. important. to.
clean. the. system. using. suitable. products.
such. as,. for. example,. Sentinel X300 (new
systems), X400 and X800 (old systems) or
Fernox Cleaner F3..
Complete. instructions. are. provided. with.
the. products. but,. for. further. informa-
tion,. you. may. directly. contact. SENTINEL.
PERFORMANCE. SOLUTIONS. LTD. or.
FERNOX.COOKSON.ELECTRONICS..
For. long-term. protection. agains. corrosion.
and.deposits,.the.use.of.inhibitors.such.as.
403
640
90
Outdoors
S3
G
SYSTEM CONNECTIONS
155
403
640
Fig..4
ES
M
ENG
R
41