10.2
Dimensional drawings
8027352/2022-05-19 | SICK
Subject to change without notice
Table 7: Technical data
CSM
Sensing range
Light spot size
Supply voltage U
B
Output current I
max.
Current consumption
Switching frequency
Jitter
Max. response time
External teach (ET)
ET: Voltage level
Output function
Switching output (voltage)
IO-Link
Enclosure rating
Protection class
Ambient temperature, operation
1)
Limit value:
12 V (-10 %) ... 24 V (+20 %). Limit values
Reverse polarity protected U
B
Residual ripple max. 5 V
ss
2)
At supply voltage > 24 V, I
max
3)
Without load
4)
With a light/dark ratio of 1:1.
5)
Signal transit time with resistive load
CSM-xxx1:
CSM-xxx1xx1x:
-xxx1xxxx
12,5 mm
9.4 x 1.9 mm
DC 12 ... 24 V
ET < 30 ms: no function, debouncing
30 ms > ET > 3 s: 1-point-teach
ET < 3 s: dynamic teach
Teach: U = 10,8 V ... < U
Teach: U < 2 V
Run: U = > U
CSM-xPxxxxxx = PNP
CSM-xNxxxxxx = NPN
PNP: High = U
NPN: High = approx. U
CSM-xxxx7xxx = ✓
–10 °C ... +55 °C
connections
= 50 mA. I
is consumption count of all Qn.
max
O P E R A T I N G I N S T R U C T I O N S | CSM
OPERATING INSTRUCTIONS
-xxxBxxxx
15 mm
10.1 x 4.9 mm
1)
100 mA
2)
< 30 mA
3)
1,7 kHz
4)
150 μs
300 μs
5)
PNP:
V
Run: U < 2 V
NPN:
- 2 V
V
- ≤ 3 V / Low approx. 0 V
V
/ Low ≤ 3 V
V
IP 67