Problem
Sudden drop in gas
pressure or reduced
flame height
Potential cause
No gas.
The overcurrent
protection may have
been activated.
Solution
Check the gas level in
the liquid gas tank.
Turn the control dial
to the "OFF" position, 
wait 30 seconds and
re-ignite the device.
If the flame height is 
still reduced, reset the
overflow protection 
by turning the control
knob and the gas bottle
valve to the "OFF" 
position. Disconnect
the gas pressure
regulator from the
device. Turn the control
knob to the "HIGH"
position. Wait at least
5 minutes. Then turn
the control dial to
the "OFF" position. 
Reconnect the gas
pressure regulator
to the device. Carry
out a leakage test.
Slowly turn the gas
bottle valve to the
"ON" position. Wait 
30 seconds and then 
press the igniter.
EN
47