OPERATION

Leak test
Before performing a leak test, make sure that there are no sparks and that you
are in a spacious outdoor area.
Connect the propane gas bottle to the gas pressure regulator and turn the
valve on the device to the "OFF" position. Spray or brush all connections with
a soap solution. Turn on the gas supply. If bubbles appear at any connection,
there may be a leak. If you smell gas or detect a leak, turn off the gas valve,
disconnect the gas bottle from the appliance and do not use the appliance until
the leak is fixed.
Do not use the gas fireplace without checking the gas hose. If there are signs of 
wear or tear, you must replace the hose.
Instructions for use
Pumice stones / lava stones / lava glass can jump out when the device is ignited 
and hit bystanders in the face. Stay away from the device for the first 20 
minutes after lighting.
The flame height should be yellow / blue in colour and between 5-25 cm high. 
Wait 50 minutes after the flame has gone out before placing a lid (if present) or 
protective cover on the device.