Trouble details
Salty water
1.
2.
3.
4.
Drain port
1.
continually drain
2.
3.
54 OLYMPIA PLUS-CEASA
All manuals and user guides at all-guides.com
Cause
Low inlet pressure.
Drain pipe or limiting washer
hindered.
Excessive amount of saturated
salt solution in brine tank.
Short time of fast rinse.
The blackout control valve is not
reset.
Leakage happens in control
valve.
Foreign material gets stuck in
control valve.
Solution
Install pressure pump.
1.
Eliminate block.
2.
Decrease amount of refill water.
3.
Extend fast rinse time.
4.
Adjust program position to service.
1.
Replace control valve.
2.
Eliminate foreign material.
3.