Values
Under the Technician model (L2)
1. Select "Set Resin Volume" parameter by (▼▲)
Set Resin Volume
2. Press "validation" and adjust (▼▲) the resin volume (LT4)
3. Press "validation" to return to the Technician mode ( L2)
Under the Technician model (L2)
Set Brine
1. Select "Set Brine D. Type" parameter by (▼▲)
D. Type
2. Press "validation" and select up-flow or down-flow (LT5)
3. Press "validation" to return to the Technician mode ( L2)
Under the Technician model (L2)
Set Backwash Time
1. Select "Set Backwash Time" parameter by (▼▲)
2. Press "validation" and adjust time according to the
3. Press "validation" to return to the technician mode (L2)
Under the Technician model ( L2)
1. Select "Set B.S.R.T" parameter by (▼▲)
Set B.S.R.T
2. Press "validation" and adjust time according to the
3. Press "validation" to return to the Technician mode (L2)
Under the Technician model (L2)
1. Select "Set B.R.Time" parameter by (▼▲)
Set B.R. Time
2. Press "validation" and adjust time according to the
3. Press "validation" to return to the Technician mode (L2)
Under the Technician model ( L2)
1. Select "Set F.R.Time" parameter by (▼▲)
Set. F.R. Time
2. Press "validation" and adjust time according to the
3. Press "validate" to adjust seconds
4. Press "validation" to return to the Technician mode ( L2)
Under the Technician model (L2)
1. Select "Set F.R.Time" parameter by (▼▲)
2. Press "validation" and adjust (▼▲) the backwash interval (LT10)
Interval B.W. Times
3. Press "validation" to return to the Technician mode (L2)
Under the Technician model (L2)
1. Select "Set F.R.Time" parameter by (▼▲)
2. Press "validation" and adjust (▼▲) the days between Regenerations (LT11)
Interval Regen. D.
3. Press "validation" to return to the Technician mode (L2)
All manuals and user guides at all-guides.com
Programming steps
Annex I
(LT6)
Annex I
(LT7)
Annex I
(LT8)
Annex I
(LT9)
OLYMPIA PLUS-CEASA 47
Screen
LT4
Set Resin Volumet
x L
LT5
Set Brine D.
Type
● up-flow
○ down-flow
LT6
Set Backwash Time
XX Minutes
LT7
Set B.S.R.T
XX Minutos
LT8
Set B.R. Time
XX:XX Minutes
LT9
Set F.R.Time
XX Minutes
LT10
Interval B.W. Times
F-00
LT11
Interval Regen. D.
30 days