3. Installation Preparation.

To prevent personal injury and damage, ensure that
the hanging location allows the blades a clearance of
7 feet (2.13m) from the oor and 30in. (76cm) from
any wall or obstruction.
The 44 in fan is suitable for room sizes up to 225
square feet (20.9 square meters).
The 52 in fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted as a ushmount on a
regular (no-slope) ceiling only. Downrod installations
are not available for this fan.
Installation requires these tools:
Phillips screwdriver, at-head screwdriver, adjustable
pliers or wrench, stepladder, wire cutters, and rated
electrical tape.

4. Mounting Plate Installation.

Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch is
turned to the OFF position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure
the outlet box is securely attached to the building
structure and can support the full weight of the fan.
Ensure outlet box is clearly marked "Suitable for Fan
Support. " If not, it must be replaced with an approved
outlet box. Failure to do so can result in serious injury.
CAUTION: Be sure outlet box is grounded properly and
that a ground wire (GREEN or bare) is present.
Install mounting plate to outlet box using original
screws, spring washers and at washers provided
with new or original outlet box.* Pull electrical wiring
from outlet box through center hole in the mounting
plate.
Locate screw on outer edge of mounting plate closest
to the j-hook and remove that screw. Also remove
screw on outer edge of mounting plate directly
opposite the screw that was just removed. Partially
loosen the other 2 screws.
*Note: It is very important that you use the proper
hardware when installing the mounting plate as this
will support the fan.
blade edge
30
inches
7 feet
(76cm)
(2.13m)
ushmount
installation
CANNOT be
installed on
angled or
vaulted ceilings
mounting plate
at washers
spring washers
outlet box screws
page 4
44in fan
12ft. - 15ft.
(3.66m - 4.57m)
52in fan
12ft. - 20ft.
(3.66m - 6.1m)
downrod
installation