Grohe Ondus 36 072 Manual Del Usuario página 5

Idiomas disponibles

Idiomas disponibles

5. The cold water supply must be connected to the inlet
marked COLD, the hot water to the inlet marked HOT,
see fig. [7]
GROHE recommends installing isolating valves upstream
of the function unit to facilitate servicing.
6. Seal plug (A) in the unused outlet.
7. Route mixed water outlets to the faucet. Connection
of outlets must be performed from the bottom upwards.
8. Seal plug (B) in the unused outlet.
9. Route connection cable in vacant tube, see fig. [8].
Several connection cables can be connected together
(max. 10m) see Replacement parts, fold-out page I.
10. Secure the vacant tube in the function unit with clamp (C).
11. Attach the plug-in conntector to the plug power supply and
to the faucet, see fig. [9].
Flush the function unit, see fold-out pages II and III, figs. [10]
and [11].
1. Remove screw plug (D), see fold-out page II, fig. [10].
2. Remove the check valve (E) and filter (F).
3. Install the flushing plugs (G) in check valve seat recesses,
see fold-out page III, fig. [11].
4. Open the cold and hot water supply.
Flush pipes thoroughly.
5. Close the cold and hot water supply and remove the flushing
plugs (G), see fig. [11].
6. Insert the filter (F) and the check valve (E), see fold-out
page II, fig. [10].
7. Install the screw plug (D).
Open hot and cold water supply and check that
connections are watertight.
8. Fit lid and fasten with screws, see fig. [5].
Maintenance
Inspect and clean all components and replace if necessary.
Disconnect power supply.
Close isolating valves.
English
I. Thermostatic compact cartridge, see fold-out page II
and III, figs. [5] and [12].
1. Remove screws and detach lid, see fold-out page II, fig. [5].
2. Remove screw (H) and washer (H1), see fold-out page III,
fig. [12].
3. Detach plug (J1) and remove servo motor (J).
4. Loosen screw ring (K) using a 34mm tool and remove.
5. If necessary, lever out thermostatic compact cartridge (L)
via recess (L1).
Assemble in reverse order.
Observe the correct installation position of the
thermostatic compact cartridge (L), see detail (L2).
6. Connect plug (J1) to servo motor (J).
7. Connect the voltage supply and open the cold and hot water
supply, see fold-out page II, figs. [7] and [9].
8. Turn regulating nut (M) until 38 °C appears in the display
of the operating panel of the faucet, see fold-out page III,
fig. [12].
9. Install servo motor (J).
Readjustment to 38 °C is necessary after every maintenance
operation on the thermostatic compact cartridge.
II. Check valve (E), see fold-out page III, fig. [12].
1. Remove the screw plug (D).
2. Remove the check valve (E) and filter (F).
III. Servo motor (N), see fold-out page III, fig. [13].
Detach plug (N1), remove clip (N2) and and remove servo
motor (N).
IV. Solenoid valve (O), see fold-out page III, fig. [13].
Detach plug (O1), remove clip (O2) and and remove solenoid
valve (O).
Assemble in reverse order.
Replacement parts
See fold-out page I (* = special accessories).
2