Location Requirements; Electrical Requirements - Haier ESA406K Manual De Uso Y Cuidado

Acondicionador de aire para habitación
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation.
The location should provide:
■ Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.
(For model ESA406K,ESA408K,ESA406K-L,ESA408K-L,
ESA406K-T,ESA408K-T,ESA408K-E electrical outlet can be
grounded within 6 ft (183 cm))
NOTE: Do not use an extension cord.
■ Free movement of air in room to be cooled.
■ A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
■ Adequate wall support for weight of air conditioner. Air
conditioner weighs 44 lbs to 76 lbs (20.0 kg to 34.5 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
A. Cabinet louvers
Window Installation
Window opening measurements:
A
B
ESA406K ESA406K-L
MODEL
ESA408K ESA408K-L
ESA406K-T ESA408K-T
Dimension
ESA408K-E
A(inch) Min
25"(63.5cm)
36"(91.4cm)
A(inch) Max
B(inch) Min
133⁄8"(34cm)
4
A
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located either on the side or back of the air conditioner
cabinet or behind the front grille.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power Supply
Cord
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a 3 prong grounding
plug. The cord must be plugged into a mating, grounded 3 prong
outlet, grounded in accordance with all local codes and
ordinances. If a mating outlet is not available, it is the customer's
A. Width
responsibility to have a properly grounded 3 prong outlet installed
by a qualified electrical installer.
B. Height
It is the customer's responsibility:
ESA410K
ESA410K-L
ESA412K
ESA412K-L
ESA410K-T
ESA410K-E
24½"(62.2cm)
38"(96.5cm)
149⁄16"(37cm)

Electrical Requirements

Wiring Requirements
115-volt (103.5 min. to 126.5 max.)
0 to 12 amps
15-amp time-delay fuse or circuit
breaker
Use on single outlet circuit only.
To contact a qualified electrical installer.
Tabla de contenido
loading

Tabla de contenido