FILLING SOLUTION TANK
1. Lift the cover and remove the solution tank from the
machine (Figure 5).
2. Fill the solution tank with 3 gal/11 L of clean water
(122°F/50°C maximum temperature) (Figure 6). Do
not fill beyond the "MAX" fill label. Partially fill if
unable to lift a full tank.
FIG. 5
ATTENTION: Do not use the recovery tank to fill
the solution tank. Dirt from the recovery tank may
cause damage to the solution pump.
3. Pour an approved low foaming cleaning detergent
into the solution tank according to the mixing
instructions on the bottle.
WARNING: Fire Or Explosion Hazard. Do Not
Use Flammable Materials. Only Use Commercially
Available Floor Cleaners intended for machine
application.
ATTENTION: Only use approved cleaning
detergents. Machine damage due to improper
detergent usage will void the manufacturer's
warranty.
Contact your dealer for recommended cleaning
detergents.
4. Submerge the solution hose screen into the
solution tank and close the cover.
FIG. 7
Nobles Speed Scrub (03- -08)
All manuals and user guides at all-guides.com
FIG. 6
CONNECTING POWER CORD
1. Plug the supplied power cord into the machine and
attach the power cord to the strain relief clip as
shown (Figure 8).
FOR SAFETY: Do not operate machine unless
power cord is properly grounded. Only use the
manufacturer- -supplied power cord which is
designed exclusively for this machine. Do not use
additional extension cords.
2. Plug the power cord into a properly grounded wall
outlet (Figure 9).
FIG. 8
WARNING: Electrical Hazard, Do Not Operate
With Damaged Power Cord.
If the power cord is damaged or broken, it must be
replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a
hazard.
3. Wrap the power cord around the handle and cord
hook when storing machine. To remove power
cord, turn the cord hook upward (Figure 10).
FIG. 10
OPERATION
EN
Grounded
3 Hole Outlet
Grounded Pin
FIG. 9
7