Technical Data; Voltage Versions And Electrical Data; Plumbing; Drainage - Miele PWM 912 SD Plano De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
en - PWM 912

Technical data

Voltage versions and electrical data

3N AC 400 V, 50/60 Hz, SD
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
3N AC 400 V, 50/60 Hz, SI
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland

Plumbing

Models with detergent drawer (DD)
Permitted flow pressure
Maximum intake rate
Cold water connection
(to be provided on site, male thread according to DIN 44991, flat seal)
Optional hard water connection, cold
(on-site external thread according to DIN 44991, flat seal)
Hot water connection (≤ 70 °C)
(on-site external thread according to DIN 44991, flat seal)
Length of inlet hoses supplied

Drainage

Maximum drain water temperature
Waste water connection (on machine)
Drain (on site)
Maximum drainage rate

Connection for equipotential bonding

Male thread
Toothed washers
34
3N AC 400V 50/60Hz
3N AC 400V 50/60Hz
3 x ½" with ¾" threaded union
2 x ½" with ¾" threaded union (optional)
1 x ½" with ¾" threaded union
Plastic pipe HT DN 70
Connection DN 70
50/60 Hz
16 A
2,3 kW
1,5 mm²
50/60 Hz
16 A
2,3 kW
1,5 mm²
1000 kPa
47,5 l/min
1,55 m
95 °C
200 l/min
M10
M10
Tabla de contenido