Instalation
Specification of the cables for proper installation:
▪ Power connectors (positive/negative)
▪ Remote connector
▪ Output signal connectors (speakers)
▪ Fuses or circuit breakers
The use of fuse or circuit breaker is mandatory to protect the system from short
circuit and overload. Install them as close to the battery as possible.
Installation should only be done by qualified professionals with the
product turned OFF.
Speakers:
11 AWG cables
Check the minimum impedance
supported by the amplifier.
STETSOM
Radio / Player
......................................................................
..............................................................
Remote: 18 AWG
........................................
..........................................
POSITIVE:
6 AWG cable
Fuse
70A
(Máx. 30cm
of battery)
15
6 AWG
18 AWG
11 AWG
70A
NEGATIVE:
6 AWG cable
Battery
RECOMMENDED USE
OF AUXILIARY BATTERY.
Ground