VALBERG WM 612 E W205T Instrucciones De Uso página 17

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

B
Useful information
WARNING:
Foreign objects left in the pump filter can damage your
machine or cause it to make noises.
When not in use, turn off the tap, remove the inlet hose
and drain the water inside the machine to prevent
freezing.
After each use, turn off the water supply tap of the
machine.
To clean the dirty filter and drain the water:
1. Unplug the machine to disconnect the power supply.
WARNING: The temperature of the water in the machine can go
up to 90°C. To avoid the risk of burning, clean the filter after the
water in the machine has cooled down.
2. Open the filter cap.
32
EN
B
Useful information
3. Follow the steps below to drain the water.
If the product does not have a drain hose, in an emergency,
follow these steps to drain the water:
1. To make the water circulate without the filter, place a
large tray in front of the filter.
2. Turn and loosen the pump filter (counter-clockwise) until
water starts to flow. Let the water drain into the tray you
have placed in front of the filter. Place a towel on the ground
to soak up any spills.
3. When the water in the machine has been drained, pull out
the filter completely by turning it.
4. Clean all residue from inside the filter, as well as the
fibres, if any, around the impeller.
5. Put the filter back in its place.
33
EN

Hide quick links:

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Wm 612 e s205tWm 612 e b205t970262970263970264

Tabla de contenido