STEP 6:
Push the housing of the quick con-
nector for the high pressure hose to-
ward the rear and disconnect the
high pressure hose from the unit.
WINTERIZING AND
LONG-TERM STORAGE
1: Disconnect all water connections.
2: Turn on the machine for a few sec-
onds, until the water which had re-
mained in the pump exits, turn off
immediately.
3: Do not allow high pressure hose to
become kinked.
4: Store the machine and accesso-
ries in a room which does not reach
freezing temperatures. DO NOT
store near furnace or other sources
of heat as it may dry out the pump
seals.
CAUTION
Failure to follow the above directions will
result in damage to the pump assembly
and accessories and will void the war-
ranty.
Kärcher
also recommends the regular
®
practice of using a pump protector like
"Kärcher
Pump Guard" to prevent cold
®
10
English
All manuals and user guides at all-guides.com
weather damage during storage in the
winter months.
CARE AND MAINTENANCE
INSTRUCTIONS
Cleaning the water inlet filter
STEP 1:
Disconect the connector from the
water inlet.
STEP 2:
Pull out water inlet filter with flat-nose
pliers.
STEP 3:
Rinse out water inlet filter in warm
water.
STEP 4:
Reinsert water inlet filter into the wa-
ter inlet.
Maintenance
The unit is maintenance-free.