General Installation Notes; Card Presentation Test - Position Technology POSI Xtend CR-R890-BL Manual De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

An external power supply unit is required to power the PosiXtend extended
range proximity reader.
Avoid wiring the PosiXtend extended range proximity reader cables in the
same conduit with AC power cables, lock power, or signal wiring. Maintain all
reader wiring a minimum of 30cm (12
power, computer data wiring, telephone wiring and wiring to electric lock
devices.

General Installation Notes

• LED and "beeper" operations are programmed via the Centaur
software, if using another controller refer to appropriate instructions.
• Do not use "twisted pair" with either output format.
• Pull the orange wire low to illuminate the red LED.
• Pull the yellow wire low to illuminate the green LED.
• Pull both the orange and yellow wires low to illuminate the red and green
LEDs, producing an amber color.
• Pull the brown wire low to activate the "beeper".
• Follow the recommended cable types and lengths listed in the "Technical
Specifications" on page 3.
• For open collector (non-terminated output), consult your system manufacturer
for correct cable length and type.
• The data out internal circuit configurations are as shown in Figure 2 on page 25.

Card Presentation Test

Place the card parallel to the PosiXtend extended range proximity reader and
move it toward the reader until the card code displays on the controller screen. At
this point, the card is read, decoded, data transmitted to the controller and the
controller has responded accordingly. To read the card again, remove and re-insert
the card into the reader's field.
If a card or key tag is left in the reader's field for more than 5 seconds, the
green and red LEDs will flash alternatively.
"