Opening
limit switch
slide application
Operator body
To adjust the closing of the door in a millimetric way after placing the limit switch slides act on the drawing curved rod releasing the bolts and
adjusting the running through the two holes (Fig. 20)
6. PROCESS OF CARD SELF-PROGRAMMING
After having correctly placed the limit switches (paragraph 5) and tested the right running of the door and the electric connections on the
inputs/outputs, make the following:
1. Power supply the control unit MINI GATE 24V
2. Position the door next to the stop in closing using the push buttons S2 and S3 (50cm ca.)
3. Bring Dip Switch 4 on ON position
4. Make sure that during the learning process the stop, photocell, safety edge, etc. orders are not set up.
5. Push button S1
6. The door will execute the closing manoeuvre until reaching the limit switch
7. At this point, an opening and a closing manoeuvre will be executed automatically
8. When the door will stop and will be completely closed, bring Dip switch 4 on OFF position again.
9. The automation is ready to work
Make the necessary regulations through the trimmers and the Dip Switches.