Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
OPERATING LOGICS
AUTOMATIC LOGIC:
SEMIAUTOMATIC LOGIC: A start order opens, a start order closes.
INPUTS
START:
it sets up the opening/closing of the automation
STOP:
it stops the automation whenever it is pushed.
A start order is necessary to reset the movement.
PHOTOCELL:
if it is set up during the closing of the automation, it causes the reversing of the movement, during the pause phase it prevents the
closing, during the opening phase it is not managed.
SAFETY EDGE: if it is set up during the opening/closing phase, it stops the movement and reverses for about 1,5 s.
A start order is necessary to reset the movement.
OUTPUTS
24V:
24V
FLASHING LAMP: During the opening phase, it flashes once a second; during the closing phase, it flashes twice a second. When the automation
is opened and in automatic logic, the flashing lamp stays on for all the pause time. If DIP2 is set on ON there will be a pre-
flashing of 3 s before the door starts to move.
GARDEN LIGHT: It switches on and stays on during the whole moving of the door. At the end of the closing cycle, it stays on for the time set by
DIP3 (OFF=1min. ON=3min).
SETTING
TRIMMER P1:
It regulates the intervention threshold of the anti-crushing detector.
Trimmer completely turned anti-clockwise=high sensibility (low push in case of obstacle).
Trimmer completely turned clockwise=low sensibility (high push in case of obstacle).
After three consecutive interventions of the anti-crushing detector, even if in automatic logic, the automation stays opened
waiting for orders. Regulate the sensibility in observance with the current laws.
TRIMMER P2:
Motor speed regulation.
Trimmer completely turned anti-clockwise=low speed
Trimmer completely turned clockwise=high speed
NOTICE: Be careful to regulate the operating high speed as it must be fit to the mechanical structure of the door on which the automation
is installed and with reference to the current laws.
TRIMMER P3:
Regulate the pause time (only in automatic logic)
Trimmer completely turned anti-clockwise=0 s
Trimmer completely turned clockwise=3 min
NOTICE: The setting of Trimmers and Dip Switches are read when the automation has stopped
S1 PUSH BUTTON: it sets up the self-programming process (with DIP4= ON)
It sets up the opening/closing of the automation (with DIP4= ON)
S2 PUSH BUTTON: hand opening push button with low speed to use only to test the right movement of the door during the installation phase (only
with DIP4 ON).
S3 PUSH BUTTON: hand closing push button with low speed to use only to test the right movement of the door during the installation phase (only
with DIP4 ON).
5. LIMIT SWITCH MOUNTING
- Keep push button S2 pressed until the desired
opening position has been reached;
- fix the limit switch slide (Fig. 18) as near as
possible to the operator body near the switch
wheel as shown in Fig. 19a
Limit switch in closing
Keep push button S3 pressed until the desired
closing position has been reached;
- fix the limit switch slide (Fig. 18) as near as
possible to the operator body near the switch
wheel as shown in Fig. 19b
67410620
®
A start order opens, executes the pause time set with P3 trimmer and closes.
During the opening or the pause phase, a further start order is ignored; during the opening phase it opens again.
A start during the opening phase stops the movement, during the closing phase it opens again.
max 200mA accessories power supply output
CORONA
Rev 09 - 03/2011
Limit switch
slide
Fig. 18
ENGLISH
17