23
WIRING TO THE "POTENTIOMETER + ON/OFF" CONTROL BOX TYPE 503 (CODE 12826)
COLLEGAMENTO ALLA SCATOLA COMANDI TIPO 503 CON POTENZIOMETRO
E TASTO ON/ OFF (CODICE 12826)
PCB/SCHEDA
1
2 POLES SWITCH (DPST)
2
DRY CONTACT FOR ALARM SIGNALLING
(250VAC, max current 3A)
24
WIRING TO THE EXTERNAL POTENTIOMETER TYPE DIN (CODE 12828)
COLLEGAMENTO AL POTENZIOMETRO ESTERNO TIPO DIN (CODICE 12828)
PCB/SCHEDA
1
2 POLES SWITCH (DPST)
2
DRY CONTACT FOR ALARM SIGNALLING
(250VAC, max current 3A)
78
LINEO 315 ES
2
LINEO 315 ES
2
PCB Control Port Description
---------------------------------------
P0 = Potentiometer 0V = GND
PI = Potentiometer Input Signal = 0-10V
P10 = Potentiometer 10V = +10V
S1-S2 = dry contact for MAX/MIN speed
R1-R2 = dry contact for optional Alarm
SURFACE MOUNTING or FLUSH TYPE 503
MONTAGGIO A PARETE oppure A INCASSO 503
CONTROL BOX/SCATOLA COMANDI
BNC
BNO
BC
SC
S1
S2
S3
POTENTIOMETER/POTENZIOMETRO
R: 10 Kohm
Switch
10A / 12VDC
4A / 250VAC
Us
+(OUT)
-(GND)
L1
N1
L
N
COVER/COPERCHIO
SURFACE MOUNTING or FLUSH TYPE DIN
MONTAGGIO A PARETE oppure
A INCASSO DIN
COVER / COPERCHIO
1
N
L
1