User manual
1 . 2.- Amplifier technical specifications Ref. 5075
Frequency range:
Gain:
Amplifier
Regulation margin:
Output level (60 dBc):
1 . 3.- Power supply unit Ref. 5029
Power
Mains voltage:
supply
Output voltages:
2.- SYSTEM COMPOSITION
Ref. 5096 .... Ch. Proc. 2 in / 2 out. (46 - 68 / 174 - 862 MHz)
Ref. 5075 .... Hybrid Amplifier
Ref. 5029 .... Power Supply Unit
Ref. 5301
47 ... 862 MHz
45 ± 2 dB
20 dB
105 dBµV (42 CH CENELEC)
230 ± 15 % V~
5V, 15V, 18V, 24V
(47 - 862 MHz)
(230 V ± 15 % - 50/60 Hz)
(24 V
- 0,55 A)
(18 V
- 0,8 A)
(1)
(15 V
- 4,2 A)
( 5 V
- 6,6 A)
Ref. 5072
Ref. 5073
Analogue Channel Processor
Connector:
Powering:
Consumption at 15 Vdc:
Test socket output:
Maximum currents:
Ref. 7234 .... Portable Universal Programming Unit
Ref. 5071 .... Wall Support (10 mod. + P.S.U.)
Ref. 5239 .... Wall Support (12 mod. + P.S.U.)
Ref. 5073 .... Blank plate
Ref. 5301 .... 19" sub-rack frame
Ref. 8250 .... 19" subrack for wall mount
Ref. 5072 .... Wall mount cabinet including wall suppor
Ref. 5074 .... Interconnecting link
Ref. 5255 .... T03/T05 link cable
Ref. 5052 .... Headend Control system PAL
(1)
When the voltages 24V
necessary to take the power of these voltages away from 15V
20
"F"
15 V
750 mA
-30 dB
24V
(0.55 A)
18V
(0.8 A)
15V
(4.2 A)
5V
(6.6 A)
and/or 18V
, are being used, it is
(1)