Inserting spring clamp elements on the I/O module
Two spring clamp elements are included separately on delivery for
new I/O modules.
1. Place the supplied spring clamp elements on the I/O module
and slide them into the slot until they engage
The spring clamp elements are now captive.
Notice!
2. Always pull the spring clamp elements up to the stop before
combining the modules.
Mounting a new I/O module
1. Check the part number on the rating plate to make sure that
you are exchanging the correct I/O module.
2. Mount the labels from the old I/O module onto the new I/O
module or label the new I/O module (
3. Lift up both spring clamp elements on the new I/O module until
the stop
.
6
4. Place the new I/O module on the mounting surface and slide it
to the right onto the unit
correctly.
5. Press down both spring clamp elements until the stop
The module is now connected to the unit.
6. Repeat steps
3.
to
5.
for the previously removed modules.
7. Retighten the end plate and retaining brackets (if required) to
the mounting surface.
8. Reconnect the electrical connections on the unit according to
the labels.
Extending the unit by an I/O module
We recommend adding I/O modules on the left to extend
the unit.
Disassembling the end plate
1. Remove the screws used to mount the left end plate to the
mounting surface.
2. Loosen the spring clamp elements, e.g. using a screwdriver,
between the I/O module and the left end plate, and pull up both
spring clamp elements to the stop
3. Pull out the end plate to the left until it is no longer connected
to the I/O module.
Inserting spring clamp elements on the I/O module
Two spring clamp elements are included separately on delivery for
new I/O modules.
1. Place the supplied spring clamp elements on the I/O module
and slide them into the slot until they engage
The spring clamp elements are now captive.
Notice!
2. Always pull the spring clamp elements up to the stop before
combining the modules.
.
8
–4).
4
. Ensure that the seals are inserted
9
.
6
.
8
Mounting a new I/O module
Mechanical loads!
Damage to the module!
O
Use retaining brackets to mount the device to the mounting
surface when assembling more than three I/O modules. The
maximum permissible space between the retaining
brackets is 150 mm.
1. Check the part number on the rating plate to make sure that
you are installing the correct I/O module.
2. Label the I/O module in accordance with the customer-specific
documentation
– the equipment ID field (
– the plug ID fields (
– and all round plug connectors
3. Lift up both spring clamp elements on the new I/O module until
the stop
.
.
6
10
4. Place the new I/O module on the mounting surface and slide it
to the right onto the last I/O module
are inserted correctly.
5. Press down both spring clamp elements until the stop
The module is now connected to the unit.
6. Repeat steps
7. If needed, assemble retaining brackets on the I/O modules.
8. Retighten the end plate and retaining brackets (if required) to
the mounting surface.
9. Reconnect the electrical connections on the unit according to
the labels.
The new module must be configured in the controller. Your
customer-specific documentation is required for this step.
Follow the corresponding section in the system manual for
the bus coupler and the I/O module.
NOTICE
–4),
4
–6)
4
. Ensure that the seals
9
3.
to
5.
for the end plate.
11
.