Simu 5055191C Traducción Del Manual Original página 8

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
6
T3.5 DC EHz motor functions
6.1 - With a well charged battery, the possible commands are: Up, stop and down. It is also possible to set an intermediate
position (see §7).
6.2 - Frost detection function: The motor stops if the shutter is jammed by ice during opening.
6.3 - Detection of obstructions function: Jamming of the shutter due to the presence of an obstruction when closing the
shutter causes the motor to stop and then run in the reverse direction.
6.4 - Battery protection against excessive discharge: Before each lifting or lowering of the shutter, the motor checks the
voltage of the battery.
If the voltage is below 11.5V: The motor will pause at the beginning of each command to lift the shutter. The shutter can
only be closed by pressing several times on the "down" button.
If the voltage is below 10V: The receiver won't accept any commands.
In these two cases, use the emergency charger in order to perform a quick battery recharge. Operation of the motor
will return to normal only if the battery voltage goes above 12V.
Recording and controling intermediate position
7
Recording:
- Position the motor on the wanted
position.
- Press 5 seconds on the "stop" key.
The motor will run for 0.5 second in
one direction and then in the other.
Re-adjustement of end limits
8
8.1 - Re-adjustement of UP end limits:
(assemblies B and D only)
1
2
5s
8.2 - Re-adjustement of DOWN end limits:
(assemblies C and D only)
1
2
5s
The re-adjustment of end limits is automatic every 56 cycles (during 3 cycles) or after a power supply
failure for the following installation : Up end limit, mounting A and C, Down end limit, mounting A and B.
9
Cancelling programming
9.1 - Switch off the power supply to the motor for 2 seconds.
- Switch on the power supply to the motor for 7 seconds.
- Switch off the power supply to the motor for 2 seconds.
- Switch the power to the motor back on.
The motor will run for 5 seconds in random direction and is now in the "cancelling" mode.
9.2- Then, validate the cancelling of the affected motor from the individual control or from a new transmitter
- Press the "PROG" key of the transmitter more than 7 seconds.
Maintain the pressure until the motor will first run for 0.5 second in
one direction and then in the other, and a few second later, it will
run again in both direction. The motor is now as it was originally
configured, and no transmitter and no settings is saved in its
memory and is ready for a new programming (§3).
5s
3
4
2s
3
4
2s
Controling:
- Press on the "stop" key for
0.5 s. the motor goes to the
intermediate position.
1- Position the motor on the UP end limit previously set in
§3.3 with the UP key.
2- Press simultaneously for 5 seconds the UP and DOWN
keys, the motor will run for 0.5 second in one direction and
then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Validate the new position by pressing 2 seconds the STOP
key. The motor will run for 0.5 second in one direction and
then in the other direction. The new end limits setting is
memorized.
1- Position the motor on the DOWN end limit previously set
in §3.3 with the DOWN key.
2- Press simultaneously for 5 secondes the UP and DOWN
keys, the motor will run for 0.5 second in one direction and
then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Validate the new position by pressing 2 seconds the STOP
key. The motor will run for 0.5 second in one direction and
then in the other direction. The new end limits setting is
memorized.
PROG
0.5s
7s
2s
7s
4/4
Tabla de contenido
loading

Este manual también es adecuado para:

F-70103

Tabla de contenido