ATTENTION
Damage to the device due to incorrect
rechargeable battery
▶ Make sure that only suitable Geberit
lithium-ion batteries of type
Milwaukee 12 V are used.
5
Insert the rechargeable battery into
the pressing tool from the rear.
Result
✓ Pressing tool is in idle state. No LED is
lit.
28
Pressing with Geberit
pressing attachments
WARNING
Risk of injury caused by flying
fragments
▶ Wear protective goggles and a
protective helmet.
WARNING
Risk of injury caused by the use
of incorrect pressing
attachments
▶ Only use pressing
attachments that correspond
to the diameter of the press-
fittings to be processed.
WARNING
Risk of fire from heat build-up
▶ Allow the pressing tool to cool
down for at least 30 minutes
after 30 minutes of continuous
operation.
▶ Do not place or store the hot
pressing tool near easily
flammable materials.
The pressing procedure can be
cancelled at any time. → See
"Cancelling the pressing procedure".
Prerequisite
Pipe ends are deburred and clean.
The pipe section and pressfitting are
fitted together according to the
installation manual of the piping system.
The pressing attachment is inserted
correctly.
1
In order to activate the tool from idle
state, tap the start button.
✓ The tool is ready for operation;
the green LED lights up.