4
Mounting
5
Electrical installation
8020357.14CS | SICK
Subject to change without notice
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of < 1,3 Nm.
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
–
Male connector connection: Note pin assignment
–
Cable: wire color
Only supply/switch on the voltage once all electrical connections have been estab‐
lished.
Explanations on connection diagram
Alarm = alarm output
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = test input
U
: 10 ... 30 V DC
B
Table 1: Connections
Wxx26x-
x4
1 = BN
4
2 = WH
3 = BU
4 = BK
5= GY
1
Wxx26x-
1 = BN
2 = BU
3 = not connected
4 = BK
5= WH
6 = GY
7 = not connected
(table 1
-
table
6)
xH
3
4
0.14 mm
2
AWG26
2
1
x9
1
6
2
5
3
4
I
= 4 A
N
MOUNTING
x5
xI
5
3
0.14 mm
2
AWG26
2
xB
7
6
1
5
2
3
4
I
= 6 A
N
4
5