P r i m i n g
Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be necessary to restore the full stroke
after considerable use, when the stroke may have been reduced and fasteners are not now being fully placed by one operation of the trigger.
O i l D e t a i l s
The recommended oil for priming is Hyspin
07992-00006). Please see safety data below.
®
H y s p i n
V G 3 2 O i l S a f e t y D a t a
First Aid
SKIN:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. Short term contact requires no
immediate attention.
INGESTION:
Seek medical attention immediately. DO NOT induce vomiting.
EYES:
Irrigate immediately with water for several minutes. Although NOT a primary irritant, minor irritation may occur following contact.
Fire
Flash point 232°C. Not classified as flammable.
Suitable extinguishing media: CO
Environment
WASTE DISPOSAL: Through authorised contractor to a licensed site. May be incinerated. Used product may be sent for reclamation.
SPILLAGE: Prevent entry into drains, sewers and water courses. Soak up with absorbent material.
Handling
Wear eye protection, impervious gloves (e.g. of PVC) and a plastic apron. Use in well ventilated area.
Storage
No special precautions.
P r i m i n g K i t
To enable you to follow the priming procedure opposite, you will need to obtain a priming kit:
®
VG32 available in 0.5 litre (part number 07992-00002) or one gallon containers (part number
, dry powder, foam or water fog. DO NOT use water jets.
2
PRIMING KIT : 07900-00688
PART Nº
DESCRIPTION
07900-00351
3 mm ALLEN KEY
07900-00700
PRIMING PUMP
07900-00224
4 mm ALLEN KEY
27