Oil Details; Hyspin Vg 32 Oil Safety Data; Waste Disposal; Priming Kit - avdel Genesis G3 HD Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

P r i m i n g
Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be necessary to restore the full
stroke after considerable use, when the stroke may be reduced and fasteners are not fully placed by one operation of the trigger.
O i l D e t a i l s
The recommended oil for priming is Hyspin VG32 available in 0.5l (part number 07992-00002) or one gallon containers (part number
07992-00006). Please see safety data below.
H y s p i n V G 3 2 O i l S a f e t y D a t a
First Aid
SKIN:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. Short term contact requires no
immediate attention.
INGESTION:
Seek medical attention immediately. DO NOT induce vomiting.
EYES:
Irrigate immediately with water for several minutes. Although NOT a primary irritant, minor irritation may occur following contact.
Fire
Flash point 232°C. Not classified as flammable.
Suitable extinguishing media: CO
Environment
WASTE DISPOSAL: Through authorised contractor to a licensed site. May be incinerated. Used product may be sent for reclamation.
SPILLAGE: Prevent entry into drains, sewers and water courses. Soak up with absorbent material.
Handling
Wear eye protection, impervious gloves (e.g. of PVC) and a plastic apron. Use in well ventilated area.
Storage
No special precautions.
P r i m i n g K i t
To enable you to follow the priming procedure opposite, you will need to obtain a priming kit:
24
, dry powder, foam or water fog. DO NOT use water jets.
2

PRIMING KIT : 07900-00688

PART Nº
DESCRIPTION
07900-00351
3mm ALLEN KEY
07900-00698
STOP NUT
07900-00700
PRIMING PUMP
07900-00224
4mm ALLEN KEY
07900-00734
MAXLOK
®
STOP NUT
Tabla de contenido
loading

Este manual también es adecuado para:

Genesis g3

Tabla de contenido