System; Part 1: General; Part 2: Performance And Operating Range - Haier Tempo Serie Guía De Especificaciones

Ocultar thumbs Ver también para Tempo Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SYSTEM

Part 1: General

1.1 Description
A. The Haier Tempo heat pump air conditioner shall be a variable capacity, mini-split type system comprised of a
single outdoor and a single wall-mounted indoor unit.
1.2 Toxicity
A. The heat pump system shall participate in RoHS compliance and listed in the directory.

Part 2: Performance and Operating Range

2.1 Operating Range
A. The heat pump shall provide cooling temperature range of 14°~115°F (-10°C~46°C)
B. The heat pump system shall be capable of providing greater than 70% capacity at 17°F (-8°C) outdoor ambient
temperature.
C. The 1U09TE1VHA and 1U12TE1VHA heat pump models shall operate normally with voltages between
104~127V.
D. The 1U18TE2VHA and 1U24TE2VHA heat pump models shall operate normally with voltages between
187~253V.
2.2 Performance
The system shall perform within the specified operating window found on the following table.
A. Cooling performance rating shall be verified following AHRI 210/240 standards of 80°F DB/67°F WB (27°/19°C)
indoor temperature and 95°F DB/75°F WB (35°/24°C) outdoor temperature.
B. Heating performance rating shall be verified following AHRI 210/240 standards of 70°F DB/60°F WB (21°/16°C)
indoor temperature and 47°F DB/43°F WB (8°/6°C) outdoor temperature.
6