WARNING : To reduce the risk of injury, only cut re-
commended materials for the blades. (see „Speci cations")
Do not attempt to cut other materials.
Cutting
Before cutting, ensure blades are properly installed.
1. Guide the cable at right angles to the cutting of the cable
cutter. Do not attempt to make angled cuts as it will damage the
workpiece and blades.
2. Pull and hold the trigger through the operation.
An LED will light when the trigger is pulled.
Once cutting has been carried out, or the tool is switched o , let the
release button go again and press the hydraulic reset button so that
the cutting bars open.
Note: Workpiece may move slightly during the cut.
Action in the event of faults
• The cable can be broached and become live, in which case always
inform the safety o cer, stop the cutting process, and initiate
suitable protective measures
GB
• Always ensure that the device is and will stay disconnected from
the power supply before approached and touching the device
• press and hold the hydraulic reset button until the cutter opens
completely
• check the battery capacity
• check the material and material thickness against the technical
data
• If it is suspected that a live cable has been cut, the cable-cutter
has to be inspected in an authorized specialist workshop
Jammed Blades
Dirt and debris can cause the blades to become jammed together
after a cut
• Press and hold the hydrulic release button to ensure the tool has
reset.
• Remove the battery pack.
• Follow the picture description to open the cutting bars
• Clean any dirt and debris from the blades before starting another
cut.
Cutting Tips
• Do not attempt to make angled cuts as it will damage the
workpiece and blades.
• Cut clean material to extend the blade life. Wipe dirt and debris
from material and blades before beginning the cut.
MAINTENANCE
Remove the battery pack before starting any work on the
appliance.
Never open the cable cutter, removable battery or charger.
Check the cable cutter for any problems such as noise or jamming of
moving parts that could be a ecting the tool.
Check the cutting tools for cracks and other signs of wear.
Clean and grease the press drives, locking bolts and cutting jaws
when you have nished work.
Check that the cutting tools are sharp and replace worn cutting
tools.
English
12
Replace the cutting tools when they become chipped or damaged.
Always replace cutting tools as a set. Use only MILWAUKEE cutting
tools.
Check that the cutting jaws and the press drives move smoothly.
To avoid injury and damage, never immerse the tool, removable
battery or charger in liquid or allow liquid to penetrate them.
The ventilation slots of the machine must be kept clear at all times.
The device contains hydraulic uid. Hydraulic uids pose a hazard
to groundwater. Uncontrolled draining or improper disposal is
punishable by law.
Service must be performed at least annually or after 5,000 cutting
processes.
Service and repair work may only be carried out by authorised
specialist workshops.
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on the
label and order the drawing at your local service agents or directly
at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Win-
nenden, Germany.
BATTERIES
Temperatures in excess of 50°C (122°F) reduce the performance of
the battery pack. Avoid extended exposure to heat or sunshine (risk
of overheating).
The contacts of chargers and battery packs must be kept clean.
For an optimum life-time, the battery packs have to be fully char-
ged, after use. Battery packs which have not been used for some
time should be recharged before use.
To obtain the longest possible battery life remove the battery pack
from the charger once it is fully charged.
For battery pack storage longer than 30 days:, Store the battery
pack where the temperature is below 27°C and away from
moisture, Store the battery packs in a 30% - 50% charged conditi-
on, Every six months of storage, charge the pack as normal.
Do not dispose of used battery packs in the household refuse or
by burning them. Milwaukee Distributors o er to retrieve old
batteries to protect our environment.
Do not store the battery pack together with metal objects (short
circuit risk).
Battery acid may leak from damaged batteries under extreme load
or extreme temperatures. In case of contact with battery acid wash
it o immediately with soap and water. In case of eye contact rinse
thoroughly for at least 10 minutes and immediately seek medical
attention.
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Tabla de contenido