Haier EST08XCP Manual De Uso Y Cuidado página 5

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Wire
Bundle
Wire
Bundle
If your existing sleeve has a rear grille and you wish
to retain: redirect the louvers to 60 angle as shown
in Fig C.
5.If the depth of your existing wall sleeve is less than or equal
to 20",skip to step 7.Otherwise,cut the baffles and the support
blocks according to length"A" in the table below.
Depth"D" of the
Length"A"
existing wall
(inches)
sleeve(inches)
5 8
20<D<20
5 8
3 4
20
<D<21
3 4
21
<D<24
6.Remove the backing from the support blocks and attach
them to the inside of the wall sleeve as shown FIG E.Slide the
baffle into solts of the support blocks.
i
D"
l
Wall
Sleeve
Wall
Wire
Bundle
Wire
Bundle
Fig.B
Fig.C
A
3 4
A
1-
3 4
4
Fig.D
Tapered Spacer
Block Board
Tapered Spacer
Block
Fig.E
7.Install the new unit into the wall sleeve.
8.Install the 1"x1
"x84"long stuffer seal between the wall
1/2
sleeve and the unit.
9.To assemble trim,snap the tab of each piece into the slot of
the other piece as shown below.2-Trim frames are supplied
with unit.use the trim frame that best fits your sleeve.
Slide trim over the front of the air conditioner until trim is flush
with sleeve as shown below.
Assemble Trim
Note:Be sure to route the cord through the trim frame before
placing the trim frame on the unit.
Fig.F
5
Tabla de contenido
loading

Este manual también es adecuado para:

Est10xcpEst12xcpEst10vcpEst12vcp

Tabla de contenido