The quick change drill chuck may be damaged.
Pressing excessively on the tool will not speed up
•
the drilling. In fact, this excessive pressure will only
serve to damage the tip of your bit, decrease the
tool performance and shorten the service life of the
tool.
There is a tremendous twisting force exerted on
•
the tool/bit at the time of hole breakthrough. Hold
the tool firmly and exert care when the bit begins to
break through the workpiece.
Always secure small workpieces in a vise or similar
•
hold-down device.
Diamond core drilling
When performing diamond core drilling operations,
always set the change lever to the
"rotation only" action.
CAUTION:
If performing diamond core drilling operations
•
using "rotation with hammering" action, the
diamond core bit may be damaged.
MAINTENANCE
CAUTION:
Always be sure that the tool is switched off and
•
unplugged before attempting to perform inspection
or maintenance.
Lubrication
CAUTION:
This servicing should be performed by Makita
•
Authorized or Factory Service Centers only.
This tool requires no hourly or daily lubrication because
it has a grease-packed lubrication system. Lubricate the
tool every time the carbon brushes are replaced.
Run the tool for several minutes to warm it up. Switch off
and unplug the tool.
1
008601
Loosen the four screws and remove the handle. Note
that the top screws are different from other screws.
position to use
1. Screws
1
1
008607
Disconnect the connector by pulling them.
1
008602
Loosen the two screws
remove the crank cap cover.
008603
Align the change lever with the symbol
five screws and then remove the crank cap.
008604
CAUTION:
Always remove the crank cap only after aligning
•
the change lever with the symbol
it forcibly without aligning the change lever with the
symbol
. Failure to do so does not allow
reassembling.
9
1. Connector
1. Crank cap cover
2. Screws
2
on crank cap cover and
1. Screws
1
, loosen the
. Never remove