Masterbuilt MWS 250S Manual De Instrucciones página 26

Tabla de contenido
PELLET SMOKER OPERATION - READ & FOLLOW ALL INSTRUCTIONS CAREFULLY
SMOKE PROGRAM OPTIONS
To help you develop an understanding of the smoke program, we have defined each setting below.
In addition, here are some key points to explain how this program works, and can be used, to master
your pellet smoking experience.
• The main reason for changing the SP setting is to adapt to your outside climate.
• Pellets will only produce heavy smoke when they are initially heated.
• The SP settings (SP 0 - SP 9) specify the auger cycle time during the smoke cycle. Based on our
testing, we have programmed your smoker to default to SP 4 for optimum smoke in most
climates.
• In a colder climate, the crucible will cool too much, causing the pellets from the previous cycle to
completely extinguish before igniting the fresh pellets. You need to increase your SP setting for
more smoke.
• In a hotter climate, the crucible will not cool enough, allowing the fresh pellets to ignite quickly.
Therefore, minimal or no smoke is produced. You need to decrease your SP setting for more
smoke.
SP Setting Table:
SP 0: Moves the pellets to the crucible for 15 seconds, then the auger rests for 45 seconds.
SP 1: Moves the pellets to the crucible for 15 seconds, then the auger rests for 55 seconds.
SP 2: Moves the pellets to the crucible for 15 seconds, then the auger rests for 65 seconds.
SP 3: Moves the pellets to the crucible for 15 seconds, then the auger rests for 75 seconds.
SP 4: Moves the pellets to the crucible for 15 seconds, then the auger rests for 85 seconds. (Default)
SP 5: Moves the pellets to the crucible for 15 seconds, then the auger rests for 95 seconds.
SP 6: Moves the pellets to the crucible for 15 seconds, then the auger rests for 105 seconds.
SP 7: Moves the pellets to the crucible for 15 seconds, then the auger rests for 115 seconds.
SP 8: Moves the pellets to the crucible for 15 seconds, then the auger rests for 125 seconds.
SP 9: Moves the pellets to the crucible for 15 seconds, then the auger rests for 135 seconds.
To change the SP (smoke program) setting:
1. Press the
smoke button. You should see the letter "S" on the display screen.
2. Press the
temperature button. Using the
3. Press the
temperature button again. You have successfully changed the smoke program.
26
up and
down arrows change the SP setting.
Tabla de contenido
loading

Este manual también es adecuado para:

Mws 255sMb20252118Mb20254916Mb21250918

Tabla de contenido