3.17 Nike Mini 24 series technical data.
ES
Rated heating power
Min. heating power
Rated heat output (useful)
Min. heat output (useful)
PT
Useful thermal efficiency at rated output
Useful thermal efficiency at 30% rated output
Heat loss at casing with burner On/Off
GR
Heat loss at flue with burner On/Off
Gas injector diameter
PL
Supply pressure
Max. working pressure heating circuit
TR
Max. working temperature heating circuit
Adjustable heating temperature
Total volume heating expansion tank
Heating expansion tank precharge
CZ
Generator water capacity
Head available with flow rate 1000/h
Hot water production available heat output
Hot water hot water adjustable temperature
CS
Hot water circuit flow limiter
Hot water circuit min. pressure (dynamic)
Hot water circuit max. working pressure
Min. draw of hot water
SI
Specific capacity (∆T 30°C)
Drawing capacity in continuous duty (∆T 30°C)
Weight of boiler full
Weight of boiler empty
HU
Electrical connection
Rated absorption
RU
Installed electrical power
Power absorbed by circulation pump
Equipment electrical system protection
RO
Mass flow of fumes at rated power
Mass flow of fumes at min. power
IE
CO
at Q. Rated/Min.
2
CO with 0% O
at Q. Rated/Min.
2
NOX with 0% O2 at Q. Rated/Min.
Temperature of fumes at rated power
Temperature of fumes at min. power
Boiler fumes circuit resistance
NO
X class
NO
weighted
X
CO weighted
Type of appliance
Category
- Flue temperature values refer to air inlet temperatures of 15°C.
- The data relative to hot water performance refer to a dynamic inlet pres-
sure of 2 bar and an inlet temperature of 15°C; the values are measured
directly at the boiler outlet considering that to obtain the declared data
mixing with cold water is necessary.
198
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
G20
mm
1,30
mbar (mm H
O)
20 (204)
2
bar
°C
°C
l
bar
l
kPa (m H
O)
2
kW (kcal/h)
°C
l/min
bar
bar
l/min
l/min
l/min
kg
kg
V/Hz
A
W
W
-
G20
kg/h
75
kg/h
68
%
4,9 / 2,15
ppm
50 / 40
ppm
260 / 155
°C
109
°C
82
Pa
-
mg/kWh
mg/kWh
B11BS
III1a2H3+
- The max. sound level emitted during boiler operation is < 55dBA. The
sound level value is referred to semianechoic chamber tests with boiler
operating at max. heat output, with extension of fume exhaust system
according to product standards.
26,2 (22551)
10,8 (9324)
23,6 (20296)
9,3 (8000)
90,0
89,0
1,8 / 0,85
8,2 / 0,60
G30
G31
0,77
0,77
29 (296)
37 (377)
3
90
38 - 85
4,5
1,0
2
17,6 (1,79)
23,6 (20296)
38 - 77
7,1
0,3
10
1,5
11,2
11,4
32,7
30
230/50
0,33
75
73
IPX4D
G30
G31
76
76
72
70
5,6 / 2,35
5,5 / 2,40
100 / 70
40 / 45
350 / 145
312 / 170
108
107
78
80
1,3
3
101
54