Delta 50560 Serie Instrucciones página 47

Ocultar thumbs Ver también para 50560 Serie:
ASME A112.18.1 / CSA B125.1
ASSE 1016 (Type -P- or -T-)
Write purchased model number here.
Table of Contents:
Warranties ................................................................................. Page 2
Installation Instructions .............................................................   P ages 3 - 7
Clean and care........................................................................... Page 8
Maintenance ..............................................................................   P age 8
Cartridge Summary Reference Sheet .......................................   P age 8
To order replacement parts, visit www.deltafaucet.com
THIS VALVE MEETS OR EXCEEDS THE
FOLLOWING STANDARDS: ASME A112.18.1/
CSA B125.1 and ASSE 1016 (Type -P- or -T-).
CAUTION: This system/device must be set by the
installer to ensure safe, maximum temperature.
Any change in the setting may raise the discharge
temperature above the limit considered safe and
may lead to hot water burns.
NOTICE TO INSTALLER: CAUTION!–As the
installer of this valve, it is your responsibility
to properly INSTALL and ADJUST this valve
per the instructions given. This valve does
not automatically adjust for inlet temperature
changes, therefore, someone must make the
necessary temperature knob adjustments
at the time of installation and further adjustments
may be necessary due to seasonal water
temperature change. YOU MUST inform the
owner/user of this requirement by following
the instructions. If you or the owner/user are
unsure how to properly make these adjustments
please refer to page 6 and if still uncertain, call
us at 1-800-345-DELTA.
After installation and adjustment, you must affix
68883 Rev.F
MultiChoice
Installation Instructions
Owners Manual
17T Series
You May Need
your name, company name and the date you
adjusted the temperature knob to the caution label
provided and apply or attach the label to the back
side of the closest cabinet door and the warning
label to the water heater. Leave this Instruction
Sheet for the owner's/user's
reference.
WARNING: This pressure balanced or
thermostatic bath valve is designed
to minimize the effects of outlet water
temperature changes due to inlet pressure
changes, commonly caused by dishwashers,
washing machines, toilets and the like. It may
not provide protection from hot water burns
when there is a failure of other temperature
controlling devices elsewhere in the
plumbing system, if the temperature knob is
not properly set or if the hot water temperature
is changed after the settings are made or if the
water inlet changes due to seasonal changes.
WARNING: Do not install a shut-off device on
either outlet of this valve. When this type of
device shuts off the water flow, it can defeat
the ability of the valve to balance the hot and
cold water pressures.