Function
AC Voltage
(V AC)
DC Voltage
(V DC)
Input Impedance: 10M
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
Frequency Range: 50 to 60Hz
Resistance
Maximum Input: 600V AC RMS or 600V DC
Temperature
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
• Continuity Check: Audible signal <10Ω, max current 1.5mA
• Sampling Frequency: 3 samples per second
• Auto Power off: After ~15 minutes of inactivity
• Overload: "OL" indicated on display
• Polarity: "-" on display indicates negative polarity
• Display: 3 ½ digit, 2000 Count LCD
ELECTRICAL SPECIFICATIONS
Range
200.0mV
2.000V
20.00V
200.0V
600V
200.0mV
2.000V
20.00V
200.0V
600V
2.000A
20.00A
200.0A
400A
200.0
2.000K
20.00k
200.0k
2.000M
20.00M
-40° to 1832°F
-40° to 1000°C
Resolution
0.1mV
1mV
10mV
100mV
1V
0.1mV
1mV
10mV
100mV
1V
1mA
10mA
100mA
1A
0.1
1
10
100
1k
10k
≤0°F ±(2.8% + 12 digits)
1°F
1°C
Accuracy
±(2.5% + 10 digits)
±(2.0% + 5 digits)
±(1.0% + 8 digits)
±(1.0% + 3 digits)
±(2.5% + 30 digits)
±(2.0% + 10 digits)
±(1.2% + 5 digits)
±(1.2% + 3 digits)
±(2.0% + 5 digits)
>0°F ±(2.8% + 6 digits)
±(2.8% + 6 digits)
3