Function Modules - Lenze E94xMHE Serie Instrucciones Para El Montaje

Tabla de contenido
9
Wiring the device modules

Function modules

9.2
Function modules
Use these modules in slot þ MXI1 or þMXI2 oMMI oMSI.
Digital frequency
Connections
Pos.
Description
X9
Input for digital frequency, 9−pole Sub−D plug
X10
Output for digital frequency, 9−pole Sub−D socket
X9
5
9
1
6
SUBD09010
78
Pin
Designation
Explanation
1
B
2
A
TTL input signal by encoder or encoder simulation
3
A
4
+5 V
Regulated voltage supply for encoder
(pin 8 = sense must be used, max. control range 5 ... 9 V)
5
GND
6
Z
TTL input signal by encoder or encoder simulation
7
Z
8
The function of this cable has to be set in the basic device:
l
l
S
Sense (sensor lead for voltage regulation, Lenze setting)
l
l
Lc
Lamp control
l
E
l
Enable
9
B
TTL input signal by encoder or encoder simulation
l
E94AYFLF004
EDK94AMH24 DE/EN/FR/ES/IT 6.0
Tabla de contenido
loading

Tabla de contenido