TROUBLESHOOTING
CARE AND MAINTENANCE
If you have any questions regarding the product, please call customer service at 1-866-235-5112
PROBLEM
Unit will not turn on.
The unit is running
but there is no water
flow.
Why is water leaking
where the high
pressure hose
connects to the spray
gun?
The power washer
turns on for
2 seconds, shuts
TROUBLESHOOTING
off, and will not turn
back on. Do I have a
defective unit?
14
CORRECTIVE ACTION
1. The GFCI module on the end of the power cord must be plugged directly into an outlet.
2. Do not use an extension cord.
3. With the GFCI Connected make sure the power switch is turned on.
Note: When power switch is turned on, the power washer will turn on by itself for 1-2
seconds and shut off. This is normal.
1. Check the water source. Unclog the nozzle on the lance. (See nozzle cleaning
instructions under "Cleaning nozzles".) Or take off the nozzle and just spray out of the
spray gun. This will indicate if the problem is with the nozzle.
1. Make sure there is an o-ring at the end of the metal tip of the high pressure hose. If
no o-ring is present, the connection between the hose and spray gun will leak. O-Ring
Kits are available online at www.arblueclean.com or call Customer Service at
1-866-235-5112 to place an order.
1. It sounds like your power washer is working just fine. When the water is connected,
the accessories are assembled properly, and the power switch is turned on, the power
washer may turn on for 1 - 2 seconds to prime the pump. It automatically shuts off and
waits for the spray gun trigger to be pressed. When the trigger is pressed, water starts
flowing through the pump. The water sensor in the pump "senses" the moving water
and automatically turns the power washer on.
2. Turn the power switch to off, hold in the trigger on the spray gun, so that you have a
steady stream of water. While you are holding the trigger open on the spray gun, at the
same time, turn the power switch on.