606
U/D torch
Allows the management of the external parameter
(CH1) (parameter selected).
705
Circuit resistance calibration
Lets you calibrate the system.
Press the encoder knob to access parameter 705.
Place the tip of the wire guide in electrical contact with
the work piece.
Press and hold the torch trigger for at least 1 s.
751
Current reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set
(consult the "Interface personalisation" section).
752
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set
(consult the "Interface personalisation" section).
801
Guard limits
Allows the setting of the warning limits and of the guard
limits.
Allows the accurate control of the various welding
phases (consult the "Guard limits" section).

3.7 Synergic curves screen

1
General
Allows the selection of the required welding method.
Manual welding method
Allows the manual setting and regulation of
each individual welding parameter (MIG/
MAG).
Synergic welding method
Makes it possible to use a series of pre-settings
(synergic curves) available in the memory of the
system.
The changing and correction of the initial set-
tings proposed by the system is allowed.
1
It allows the selection of:
synergic MIG
manual MIG
Select however one of suggested synergies (5-6) in
order to take advantage of ignition potentiality,
closing arc features....
2/3
Lets you select:
- type of filler material
- gas type
46
4
Lets you select:
- wire diameter
5
- Type of filler material
- Gas type
6 Wire diameter
7 Header
(See the "Main screen" section).
NO PROGRAM
Indicates that the selected synergic program is not avail-
able or is not consistent with the other system settings.
2
Synergic curves
MIG/MAG - Pulsed MIG
G3/4 Si1 CO 2
G3/4 Si1 Ar 18%CO 2
CrNi 19 9 Ar 2%CO 2
AlMg5 Ar
AlSi5 Ar
Al99,5 Ar
CuAl8 Ar
CuSi3 Ar
Basic FCW Ar 18%CO 2
Rutil FCW Ar 18%CO 2
Metal FCW Ar 18%CO 2
CrNi 19 9 FCW Ar 18%CO 2

3.8 Programs screen

1
General
Allows the storage and management of 64 welding pro-
grams which can be personalised by the operator.
1/2/3/4 Functions
5 Number of the selected program
6 Main parameters of the selected program
7 Description of the selected program
8 Heading
(consult the "Main screen" section).
2
Program storage
Enter the "program storage" menu by pressing button
for at least 1 second.
Ø (mm)
0,8
1.0
1.2
1.6
2
3
4
7
8
9
12
13
14
17
18
19
22
23
24
27
28
29
32
33
34
37
38
39
/
/
42
44
/
/
46
48
/
/
50
52
/
/
54
56
/
/
/
/
/
/
/
/
Tabla de contenido