Extension Cords - Milwaukee 8988-20 Manual Del Operador

Pistola de calor de temperatura variable
Ocultar thumbs Ver también para 8988-20:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

• Keep work environment clean. Keep food and drink
away from work area. Wash hands, arms and face
and rinse mouth before eating and drinking. Do not
smoke, or chew gum or tobacco in the work area. Paint
scrapings and dust created from removing paint may
contain chemicals that are hazardous.
• Clean up all paint scraping and dust. DO NOT
SWEEP, DRY DUST OR VACUUM. Wet mop floors.
Use a wet cloth to clean all walls, sills and other sur-
faces where paint and dust have accumulated. Use a
high phosphate detergent, trisodium phosphate (TSP),
or a trisodium phosphate substitute to clean and mop
the work area.
• Dispose of paint scrapings properly. Following each
work session, place paint scrapings in a double plastic
bag, close it with tape or twist ties and dispose.
• Remove protective clothing and work shoes in
the work area to avoid transferring dust to other
parts of the building. Wash work clothes separately.
Wipe shoes off with a wet rag that is then washed with
the work clothes. Wash hair and body thoroughly with
soap and water.
SAVE THESE INSTRUCTIONS

EXTENSION CORDS

Grounded tools require a three wire extension
cord. Double insulated tools can use either a two
or three wire extension cord. As the distance from
the supply outlet increases, you must use a heavier
gauge extension cord. Using extension cords with
inadequately sized wire causes a serious drop in
voltage, resulting in loss of power and possible tool
damage. Refer to the table shown to determine the
required minimum wire size.
The smaller the gauge number of the wire, the greater
the capacity of the cord. For example, a 14 gauge
cord can carry a higher current than a 16 gauge cord.
When using more than one extension cord to make
up the total length, be sure each cord contains at
least the minimum wire size required. If you are using
one extension cord for more than one tool, add the
nameplate amperes and use the sum to determine
the required minimum wire size.
Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be sure
it is marked with the suffix "W-A" ("W" in Canada)
to indicate that it is acceptable for outdoor use.
• Be sure your extension cord is properly wired
and in good electrical condition. Always replace a
damaged extension cord or have it repaired by a
qualified person before using it.
• Protect your extension cords from sharp objects,
excessive heat and damp or wet areas.
Recommended Minimum Wire Gauge
For Extension Cords*
Nameplate Amps
25'
0 - 2.0
18
2.1 - 3.4
18
3.5 - 5.0
18
5.1 - 7.0
18
7.1 - 12.0
16
12.1 - 16.0
14
16.1 - 20.0
12
* Based on limiting the line voltage drop to five volts at 150%
of the rated amperes.
READ AND SAVE ALL INSTRUCTIONS
FOR FUTURE USE.
Extension Cord Length
50'
75'
100'
18
18
18
18
18
16
18
16
14
16
14
12
14
12
10
12
10
--
10
--
--
WARNING
electric shock. Check with a qualified electrician
if you are in doubt as to whether the outlet is
properly grounded. Do not modify the plug pro-
vided with the tool. Never remove the grounding
prong from the plug. Do not use the tool if the
cord or plug is damaged. If damaged, have it
repaired by a MILWAUKEE service facility before
use. If the plug will not fit the outlet, have a
proper outlet installed by a qualified electrician.
Grounded Tools (Three-Prong Plugs)
Tools marked "Grounding Required" have a three
wire cord and three prong grounding plug. The plug
must be connected to a properly grounded outlet
(See Figure A). If the tool should electrically mal-
function or break down, grounding provides a low
resistance path to carry electricity away from the
user, reducing the risk of electric shock.
The grounding prong in the plug is connected through
the green wire inside the cord to the grounding
system in the tool. The green wire in the cord must
be the only wire connected to the tool's grounding
system and must never be attached to an electrically
"live" terminal.
Your tool must be plugged into an appro-
priate outlet, properly installed and
grounded in accordance with all codes
and ordinances. The plug and outlet
should look like those in Figure A.
Double Insulated Tools (Two-Prong Plugs)
Tools marked "Double Insulated" do not require
grounding. They have a special double insulation
system which satisfies OSHA requirements and
complies with the applicable standards
of Underwriters Laboratories, Inc., the
Canadian Standard Association and
the National Electrical Code. Double
Insulated tools may be used in either
of the 120 volt outlets shown in Figures
B and C.
Cat. No. ..................................................... 8988-20
Volts AC .............................................................120
Max. Amps ........................................................12.5
Max. Watts .......................................................1500
Switch Setting .........................................................I
Temperature ............................................ Ambient
Airflow CFM*...................................................10.6
Switch Setting ........................................................II
Temperature .........120°F - 1150°F (49°C - 621°C)
Airflow CFM*...................................................10.6
Switch Setting .......................................................III
Temperature .........120°F - 1150°F (49°C - 621°C)
150'
Airflow CFM*...................................................17.5
16
14
12
12
--
--
--
4
GROUNDING
Improperly connecting the ground-
ing wire can result in the risk of
SPECIFICATIONS
* Cubic feet per minute
Fig. A
Fig. B Fig. C
Tabla de contenido
loading

Tabla de contenido