tYPe of Gas
Your natural gas grill is factory built to operate using natural gas only . Never attempt to
operate your grill on gases other than the type specified on the grill rating plates .
Your grill operates at 7" of water column pressure. If replacement of the hose becomes
necessary, factory specified parts are required . See your local dealer .
For safety and design reasons, the conversion of a Weber
Natural gas to operation using LP gas is not allowed .
what is Natural Gas?
Natural gas, often called methane, is a safe modern fuel . Natural gas is supplied by your
local utility and should be readily available if your house is already heated with gas .
Natural Gas CoNNeCtioN
Weber
®
recommends moving the grill at least 24" from the gas supply and any
combustible surfaces . After the gas supply has been run and checked for leaks in
accordance to the assembly instructions, you are ready to grill . To connect the hose
to the gas supply, pull back the outer fitting, insert the hose fitting all of the way, and
release the outer fitting . This process will produce a gas joint .
leaK CheCK PreParatioN
Check that all Burner Valves are off
Valves are shipped in the OFF position, but you should check to be sure that they are
turned off . Check by pushing in and turning clockwise . If they do not turn, they are off . If
they do turn continue turning them clockwise until they stop, then they are off .
Check the flexible hose to Manifold Connection
The natural gas hose was attached during the manuafacturing process . We do
recommend that the hose to gas manifold connnection be leak tested, following
guidelines in this Owner's Guide, prior to barbecue operation .
To perform leak checks: Slide back the collar of the quick disconnect (1) . Push male
fitting of the hose into the quick disconnect, and maintain pressure . Slide the collar
closed (2) . If it does not engage or lock, repeat procedure . Gas will not flow unless the
quick disconnect is properly engaged .
10
GaS INSTrUcTIoNS
grill from operation using
®
◆
◆
◆
1
◆
1
2
3
4
Coat this pipe nipple with gas-resistant pipe dope
5
6
1
2
3
4
Push plug until sleeve snaps forward, locking plug in socket .
When properly assembled, the plug cannot be removed without pushing the sleeve back .
To disconnect, push sleeve back and pull out plug .
2
Swivel connection
Install covers when hose is disconnected
Shut-off valve
Socket
Male connection
Socket
Sleeve
Push sleeve back
Plug
(This turns on gas automatically .)
(This automatically shuts off gas .)