Thepressure regulator a ndhoseassembly provided
withthis gasgrill mustbeused.
T his regulator
is set
for an outlet
pressure
of 11 inches water
column.
Replacement
pressure
regulators
and hose assemblies
must
be those
specified
in the parts
list.
Your regulator
is equipped
with a Q.C.C. Type 1 quick
connect
system.
It will not allow gas to flow until a
positive
seal has been made.
It has a flow-limiting
device
that will restrict
the flow of gas to 10 cubic feet
per hour (0.28
cubic meters
per hour).
TO PLACE THE CYLINDER
INTO
THE GRILL
CABINET
1.
Place the LP tank
cylinder
in the cabinet
Base.
front
of the tank valve should
face out from
the
enclosure.
2.
Wrap the tank support
ring around
the tank and
latch over its hook to secure the tank.
I
he regulator
must
enter
the
I
cylinder
valve
in a straiaht
line.
Center
this nipple
of the
regulator
into the cylinder
valve.
I Q.C.C.1 Type 1 Connector
I
I
Keep the gas cylinder
in the upright
position
at all
times.
TO CONNECT
THE CYLINDER
TO THE REGULATOR
AND
HOSE
1.
Place the cylinder
into the cabinet
following
the
information
in the assembly
instructions.
2.
Be sure the LP cylinder
is "OFF" by turning
the
hand wheel clockwise
until it stops.
3.
Be sure the burner
controls
are turned
to the "OFF"
position.
4.
Remove
the safety
cap from the cylinder
valve.
5.
Center
the nipple
of the regulator
into the cylinder.
6.
Turn the black nut clockwise
until it stops.
Hand Tighten
Only.
Do Not Use A Wrench.
Do not connect
this grill to any unregulated
sources
of propane.
Before
each use, check the gas hose for excessive
abrasion
or wear, or cuts.
Replace
a hose
assembly
showing
those
signs with the
hose assembly
specified
in the parts list before
using the grill.
Inspect
the hose assembly
by
following
it from
the LP tank
connection
to the
gas manifold
assembly.
Always
perform
the Leak Test listed below
before
using
your grill for the first time,
if the
cylinder
has been changed,
any gas
components
have been changed,
the regulator
flow-limiting
device
has been activated,
or
after a long period
of non-use.
Do not attempt
to connect
this grill to the LP
system
of a motor
home
or trailer.