General Characteristics - Cembre B70M-P24 Manual De Uso

Bomba electro-hidraulica portatil
Ocultar thumbs Ver también para B70M-P24:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Max operating pressure
Oil supply
Weight with battery
Degree of protection
Motor
Operating temperature
Battery
Battery charger supply
Oil reservoir capacity
Recommended oil
Recommended oil for
"KV" versions
Dimensions: LxWxH
Safety: the pump is fitted with a maximum pressure valve and pressure switch; MPC1 gauge, is available
upon request (see pag. 42) to check the proper setting of the pressure switch.
Acoustic Noise (Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u)
– The weighted continuous acoustic pressure level equivalent A
at the work place L
pA
– The maximum value of the weighted acoustic displacement pressure C
at the work place L
pCPeak
– The acoustic power level emitted by the machine L
is equal to .................................................................................................................................................................... 74,5 dB (A)
Hydraulic pumps manufactured by Cembre S.p.A. are developed for use with
crimping or cutting heads. According to this specific use, they do not need and are
not equipped with an oil non-return safety system.
For this reason, use in applications different from those intended (for example with hydraulic
jacks, lifting systems or similar) can be dangerous for the operator.
Cembre S.p.A. does not accept any liability arising from the use of its hydraulics pumps
for applications different from those listed in its catalogues or other documentation.

1. GENERAL CHARACTERISTICS

B70M-P24-KV
bar (psi)
litres/min
(gpm)
kg (lbs)
Volt DC
°C (°F)
Volt / Hz 220 - 240 / 50 - 60
cm
(gal.)
3
mm (inch.)
is equal to ........................................................................................................................ 63,9 dB (A)
is ....................................................................................................................................< 130 dB (C)
B70M-P24
B70M-P24A
B70M-P24A-KV
700 (10,000)
0,6 (0.16)
9,2 (20.2)
-10 to +50 (+14 to +122)
24 Volt NiMH
120 / 50 - 60
1000 (0.26)
ENI ARNICA ISO 22 or equivalent
TOTAL DIEKAN 1640 or equivalent
390x163x323 (15.3x6.4x12.7)
WA
B85M-P24
850 (12,150)
0,5 (0.13)
10 (22)
IP 54
24
220 - 240 / 50 - 60
4
Tabla de contenido
loading

Este manual también es adecuado para:

B70m-p24aB70m-p24-kvB70m-p24a-kvB85m-p24

Tabla de contenido