Dometic MPC Serie Instrucciones De Montaje página 22

Tabla de contenido
Operating the MPC01
Reading battery values
➤ Navigate to the menu page for the battery required, see chapter "Navigating within the menu"
on page 14.
I
NOTE
The "Overview of supply batteries" menu page displays an average value for all supply
batteries. The values of the starter battery (IBS_B1 connection) are not taken into
consideration on this menu page. They are displayed on the "Starter battery" menu
page.
Changing the settings for batteries A, B and C
➤ Navigate to the "Battery details" menu (page 17), see chapter "Navigating within the menu"
on page 14.
➤ Navigate to the menu page for the battery required.
➤ Press the selector button to access setting mode.
➤ Turn the selector button to mark the value to change.
➤ Set the required value, see chapter "Changing values" on page 21.
Programming the switchable outputs
You can define the switch points for switchable outputs 1–3 on the adapter board (fig. 5 1, 2, 5,
page 5). The set value (10 % – 90 %) is the total capacity of all batteries connected. If the value for
the current total capacity is greater than the set value, then the output is switched to earth. If the
value for the current total capacity is less than the set value, then the output is not connected to
earth.
➤ Navigate to the "Switchable output settings" menu page (page 18), see chapter "Navigating
within the menu" on page 14.
➤ Press the selector button to access setting mode.
➤ Turn the selector button to mark the value to change.
➤ Set the required value, see chapter "Changing values" on page 21.
22
MPC01
EN
Tabla de contenido
loading

Este manual también es adecuado para:

Mpc019102500073

Tabla de contenido