17
Technical Information
TwisTorr 804 FS On Board Controller Installation
3
4
5
6
7
8
9
Figure 59
326/344
Place the bracket on the pump bottom (the hole on the bracket
has the same diameter as the pump bottom flange);
Screw a little bit the three screws M6 in the holes on the pump
bottom;
Rotate the bracket until the controller is on the chosen position;
Tighten the screws properly;
Turn the pump again;
Plug the main cable and connect the pump cable to the pump;
Connect the mating connector with the jumper on the interlock
signal to start the pump.