Outside Station; Electronic Control Box; Installation - Extel Lesli Instrucciones De Uso

Ocultar thumbs Ver también para Lesli:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
b. Outside station
(fig. 3)
1. IR Led: night vision (light invisible to the naked eye) with dusk sensor.
2. Adjustable C-MOS camera lens
3. Speaker
4. Call button
5. Name holder and light indicator:
- if the electronic control box is battery powered, the indicator only lights after a call if the light levels are too low.
- if the electronic control box is powered using low voltage (12 or 24 V AC/DC), the name holder lights automati-
cally in the dark.
- gently lift the plastic protection using a small screw driver, place the name holder label and refit the plastic protector
6. Microphone
7. Fixture screws to mount the station on the shield
8. Terminal block to connect the wires
9. Access to adjust the camera lens
c. Electronic control box
(fig. 4)
1. Aerial
2. SMA aerial connector
3. Wire cable to connect the control box to the outside station
4. Battery compartment
5. Terminal block to connect an automated portal
6. Terminal block to connect the electric door opener or electric lock
7. Power supply terminal block (12 or 24 V AC/DC)
8. Pairing and reset buttons

4. INSTALLATION

Before installing the element in the kit, make sure the planned locations have good air ventilation, are free from
excessive dust, and are not subject to excessive vibrations.
Important : This videophone has a range of 300 m in an open space. However, the range can be reduced depend-
ing on the type and number of obstacles between, or close to, the devices. It is therefore imperative to test all the
videophone elements before fixing them in order to find the best locations for the outside station and the moni-
tor.
a. Installing the outside station and the control box on batteries
(fig. 4-5-6).
Caution: Do not use rechargeable batteries.
1. Use the shield as a template to drill 3 suitable holes on the outside of the pillar and fix the outside station.
(5-6-7 fig 6)
2. Place a silicone seal (4) between the shield and the wall to avoid water running inside. (do not use acetic acid
based silicone (vinegar smell).
3. Use the 6-conductor cable to connect the box and the outside station and make sure the colours match. (3 fig 4)
Tip: we recommend passing the wires (for the outside station and the electric door opener) through a protective
sheath in order to protect them from shocks and bad weather. Do not cut the extra 6-wire cable length to avoid
oxidation or bad contact issues. It is better to roll it into a coil between the pillar and the electronic control box
Insert 4 LR20 batteries into the electronic box to test the radio range.
The aerial must be as clear from any metal parts, sources of parasites or obstacles as possible between your con-
trol box and your home, there should especially be no contact between the aerial and tree leafs or branches. It
should also be placed sufficiently high up (about 1.60m from the ground) and in a vertical position to achieve the
best performances.
4. Once the ideal location has been found, permanently mount the equipment.