Anleitung EBH 801 Standard
08.11.2001 7:14 Uhr
Do not use in areas where there are vapours or
flammable liquids.
Always pull the plug out of the socket before
cleaning or making changes to the machine.
Chisel bits and drill bits may be flung out of the
machine accidentally and cause serious injury:
Before starting to work, always check that the
chisel or drill bit is properly locked in the chuck.
Examine the chuck regularly for signs of wear or
damage.
Never start up a hammer tool until it pressed
against a workpiece (wall, ceiling, etc.).
When you are finished, unplug the hammer drill
from the electric supply and remove the chisel or
drill bit from the machine.
Always disconnect the hammer drill from the
electric supply before you change a chisel or drill
bit.
Protect your eyes and other workers from flying
particles and splinters. Wear a helmet! Set up
partition walls!
Wear work gloves to protect fingers from bruising
and grazing.
Vibrations can injure the hand-arm system. Keep
exposure to vibrations as short as possible.
Functional principle behind the
electromagnetic hammer drill
Resetting coil
Damping and hammering spring
Hammering coil
Switching system
Hammering piston
~230 V
Damping and
hammering spring
Seite 9
Maintenance
Keep your machine clean at all times.
Never use caustic agents to clean the plastic
parts.
At the end of your work, to prevent dust deposits
you should use compressed air (max. 3 bar) to
clean out the ventilation slots with the motor
running.
Check the carbon brushes regularly (dirty or worn
carbon brushes result in excessive sparking and
speed faults).
If you discover any damage, use the enclosed
drawing and parts list to establish exactly which
spare parts are required and order them from our
Customer Service.
Fitting the handle
You can screw the handle (6) in its mounting
thread on either the left or right-hand side of the
machine.
GB