Craftsman 919.165372 Manual Del Propietário página 19

Compresor de aire montado en tanque permanentemente lubricado
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PROBLEM
Motor will not run.
CAUSE
Fuse blown, circuit
breaker tripped.
Extension cord is wrong
length or gauge.
Loose electrical
connections.
Faulty motor.
Motor overload
protection switch has
tripped
19 - ENG
CORRECTION
Check fuse box for
blown fuse and replace
as necessary. Reset cir-
cuit breaker. Do not use
a fuse or circuit breaker
with higher rating than
that specified for your
particular branch circuit.
Check for proper fuse.
You should use a time
delay fuse.
Check for low voltage
problem.
Check the extension
cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Check the extension
cord.
Check wiring connec-
tion inside terminal box.
Have checked by
a Trained Service
Technician.
Refer to "Motor
Overload Protection"
under Operation.
If motor overload
protection trips
frequently, contact
a Trained Service
Technician
1000002203

Capítulos

Tabla de contenido
loading

Tabla de contenido