PROBLEM
Pressure reading on
the regulated pressure
gauge drops when an
accessory is used.
Compressor is not sup-
plying enough air to
operate accessories.
Regulator knob has con-
tinuous air leak.
Regulator will not shut
off air outlet.
1000002203
CAUSE
It is normal for "some"
pressure drop to occur.
Prolonged excessive use
of air.
Compressor is not large
enough for air require-
ment.
Hole in hose.
Check valve restricted.
Air leaks.
Damaged regulator.
Damaged regulator.
18 - ENG
CORRECTION
If there is an excessive
amount of pressure drop
when the accessory is
used, adjust the regula-
tor following the instruc-
tions in the "Description
of Operation" paragraph
in the Operation Section.
NOTE: Adjust the regu-
lated pressure under
flow conditions (while
accessory is being
used).
Decrease amount of air
usage.
Check the accessory
air requirement. If it is
higher than the SCFM
or pressure supplied by
your air compressor, you
need a larger compres-
sor.
Check and replace if
required.
Remove and clean, or
replace.
Tighten fittings.
Replace.
Replace.